HVAC Wiki

All things related to HVAC

User Tools

Site Tools


suppliers:hvac.io:vigilia:recording

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
suppliers:hvac.io:vigilia:recording [2019/05/10 05:36] – [Step 2 : Project credentials] 52.242.19.186suppliers:hvac.io:vigilia:recording [2020/07/22 15:02] – old revision restored (2016/08/25 09:00) 95.91.41.38
Line 48: Line 48:
 To start logging a network, **begin by running Wacnet**. To start logging a network, **begin by running Wacnet**.
  
-Make sure you can see the devices on your network by checking the **[[http://localhost:47800/vigilia/configs|Explorer]]** tab. (This link will only work when you have a running Wacnet instance.)+Make sure you can see the devices on your network by checking the **[[http://localhost:47800/vigilia/configs|Explorer]]** tab.
  
 Here's an example of what you should see: Here's an example of what you should see:
  
-{{:suppliers:hvac.io:vigilia:wacnet-explorer-tab-device.png?600|}}+{{:suppliers:hvac.io:vigilia:wacnet-explorer-tab-device.png|}}
  
-Once you have validated that you can see devices from your BACnet network, go and configure a few things in the **[[http://localhost:47800/vigilia/configs|Vigilia Configs]]** page :+Then, go and configure a few things in the **[[http://localhost:47800/vigilia/configs|Vigilia Configs]]** page :
 ==== Step 1 : Connect to a Vigilia server ==== ==== Step 1 : Connect to a Vigilia server ====
  
-** Skip this step if you are using HVAC.IO's servers. (Default)**+** Skip this step if you are using HVAC.IO's servers. **
  
 The first thing to configure is a Vigilia API URL. This will tell Wacnet where it should send its data. The first thing to configure is a Vigilia API URL. This will tell Wacnet where it should send its data.
Line 88: Line 88:
 Here's an example : Here's an example :
   * Project-id : 5371147be4b0222b740851a2   * Project-id : 5371147be4b0222b740851a2
-  * Logger key: asdi34h5h+  * Logger key: asdi34h5ha
  
 Make sure Wacnet has access to the project : Make sure Wacnet has access to the project :
Line 105: Line 105:
 Depending on the size of your network, Wacnet will start scanning the devices after a few seconds. Depending on the size of your network, Wacnet will start scanning the devices after a few seconds.
  
-After a few minutes, you can validate that everything runs smoothly by checking the time taken to scan your network. See "Last scan duration" just above the start/stop buttons. After at least one scan, you should be able to load your project on the Vigilia server and see the scanned devices.+After a few minutes, you can validate that every runs smoothly by checking the time taken to scan your network. See "Last scan duration"just above the start/stop buttons. After at least one scan, you should be able to load your project on the Vigilia server and see the scanned devices.
  
  
Line 113: Line 113:
  
 === Windows === === Windows ===
-Assuming you installed the Wacnet .jar file into c:/Wacnet, you can place this script in your startup directory:+Assuming you installed the Wacnet .jar file into c:/wacnet, you can place this script in your startup directory:
  
 <file batch wacnet-startup.bat> <file batch wacnet-startup.bat>
suppliers/hvac.io/vigilia/recording.txt · Last modified: 2020/10/04 07:22 by 178.151.245.174